Below you can download free corbel font. This font uploaded 8 January 2013. Corbel font viewed 11739 times and downloaded 3953 times. See preview corbel font, write comments, or download corbel font for free. This font available for Windows 7 and Mac OS in TrueType(.ttf) and OpenType(.otf) format. Ekena Millwork Rubberwood Boston Traditional Scroll 8-in Rubberwood Boston Traditional Scroll Rubberwood Unfinished Wood Corbel. Model #COR03X08X13TSRW. Compare; Find My Store. For pricing and availability. Ekena Millwork 6-in Rubberwood Unfinished Wood Corbel. Model #BKTW01X06X06.
- Phone - 1-877-550-0600. Email - sales@udecor.com 2510 Stanley Gault Parkway Louisville, KY 40223.
- 17' Lion Corbel, Wooden Corbel, Rustic Corbel, Fireplace Surround, lion art. Large Wooden Corbel/bracket Dragon. Carved from oak wood. 2 XL WOOD CORBELS Vintage Gable Brackets Corner Brace Roof Support 20' TALL.
- Corbel is a humanist sans-serif typeface designed by Jeremy Tankard for Microsoft and released in 2005. It is part of the ClearType Font Collection, a suite of fonts from various designers released with Windows Vista.All start with the letter C to reflect that they were designed to work well with Microsoft's ClearType text rendering system, a text rendering engine designed to make text clearer.
Overview
Corbel is designed to give an uncluttered and clean appearance on screen. The letter forms are open with soft, flowing curves. It is legible, clear and functional at small sizes. At larger sizes the detailing and style of the shapes is more apparent resulting in a modern sans serif type with a wide range of possible uses.
File name | Corbel.ttf Corbelb.ttf Corbelz.ttf Corbeli.ttf Corbell.ttf Corbelli.ttf |
Styles & Weights | Corbel Corbel Bold Corbel Bold Italic Corbel Italic Corbel Light Corbel Light Italic |
Designers | Jeremy Tankard |
Copyright | © 2018 Microsoft Corporation. All rights reserved. |
Font vendor | Microsoft Corp. |
Script Tags | dlng:'Cyrl', 'Grek', 'Latn' slng:'Cyrl', 'Grek', 'Latn' |
Code pages | 1252 Latin 1 1250 Latin 2: Eastern Europe 1251 Cyrillic 1253 Greek 1254 Turkish 1257 Windows Baltic 1258 Vietnamese Mac Roman Macintosh Character Set (US Roman) |
Fixed pitch | False |
Licensing and redistribution info
- Font redistribution FAQ for Windows
- License Microsoft fonts for enterprises, web developers, for hardware & software redistribution or server installations
Products that supply this font
Product name | Font version |
---|---|
Windows 10 | See the Windows 10 page. |
Windows 8.1 | See the Windows 8.1 page. |
Windows 8 | See the Windows 8 page. |
Windows 7 | See the Windows 7 page. |
Windows Vista | 5.00 |
Windows Server 2008 | 5.00 |
Office 2007 | 1.02 |
Office Mac 2008 | 2.00 |
This typeface is also available within Office applications. For more information visit this page.
Style & weight examples
Change list:
Windows 10 version 1809 released on November 13, 2018
The following two styles were added to the Corbel font family
- Corbel Light
- Corbel Light ItalicThese styles were created by Monotype.
Windows 7
The fonts were extended to support the Vietnamese language.
Windows Vista
Corbel was introduced as part of the ClearType font collection. Initially it was available in four styles with a pan European language character set.
- Corbel
- Corbel Bold
- Corbel Bold Italic
- Corbel Italic
Introduction
Corbel is a short structural element that cantilevers out from column/wall to support load. Generally, the corbel is casted monolithically with column/wall.
There are several typical modes of failure in the corbel. The most common of which are yielding of the tension tie, failure of the end anchorages of the tension tie, either under the load point or in the column, failure of the compression strut by crushing or shearing, and local failures under the bearing plate.
The following figures shows the failure mode of corbel
Design of Corbel
The corbel must be designed to resist simultaneously Vu, a factored moment Mu and a factored horizontal tensile force Nuc. ACI Code Section 11.8 requires corbels having a/d between 1 and 2 to designed using Appendix A, strut-and-tie models, where a is the distance from the load to the face of column and d is the depth of the corbel below the tie, measured at the face of the column. Corbels having a/d less than or equal 1 may be designed using either strut-and-tie models or traditional ACI designed method, Section 11.8. This paper presents Corbels design according to traditional ACI method.
ACI Design Method
Shear Design of Corbel
To avoid the crack that occurs in the interface of the corbel and the column we must provide the shear friction reinforcement perpendicular with the cracks direction. We use coefficient of friction μ to transform the horizontal resisting force into vertical resisting force.
The nominal shear strength of shear reinforcement can be determined using equations below
Vn = Avf fy μ for vertical shear friction reinforcement, and
Vn = Avf fy (μ sin αf + cos αf) for inclined shear reinforcement
where
Vn : nominal shear strength of shear friction reinforcement
Avf : area of shear friction reinforcement
fy : yield strength of shear friction reinforcement
μ : coefficient of friction
Method | Coefficient of Friction, μ |
Concrete cast monolithic | 1.4λ |
Concrete placed against roughened hardened concrete | 1.0λ |
Concrete placed against unroughened hardened concrete | 0.6λ |
Concrete anchored to structural steel | 0.7λ |
The value of λ is 1.0 for normal weight concrete, 0.85 for sand light weight concrete and 0.75 for all light weight concrete.
The maximum nominal shear force, Vn shall not exceed the smallest of 0.2 fc’ bw d and 5.5 bw d, where
fc’ : compression strength of concrete (MPa)
bw : width of corbel section (mm)
d : effective depth of corbel (mm)
Flexural Design of Corbel
The corbel is designed to resist ultimate flexural moment result from the supported beam reaction, Vu and horizontal force from creep and shrinkage, Nuc. The minimum value of Nuc is 0.2 Vu and not greater than Vu.
Tension Reinforcement
The ultimate horizontal force, Nuc shall be resisted by tension reinforcement as follow
An = Nuc / ϕfy
Where:
An : area of tension reinforcement
Nuc : ultimate horizontal force at corbel
fy : yield strength of shear friction reinforcement
ϕ : strength reduction factor
Flexural Reinforcement
The ultimate flexure moment, Mu is
Mu = Vu av + Nuc (h – d)
Where:
Mu : ultimate flexure moment
Vu : ultimate shear force
av : distance from Vu to the face of column
Nuc : ultimate horizontal force at corbel
h : height of corbel
d : effective depth of corbel
Mu ≤ ϕ Af fy (d-a/2) where
a = Af fy / 0.85f’c b
From the equation above, area of flexural reinforcement, Afcan be determined using trial and error. As first trial, (d – a/2) can be assumed 0.9d so that
Af ≥ Mu / ϕ fy (0.9d)
For practical reason, the value of (d – a/2) can be used 0.85d
Af ≥ Mu / ϕ fy (0.85d)
After finding Avf, An, and Af, we must then calculate the primary tension reinforcement Asc from the larger of Af + An and 2Avf/3 + An
Reinforcement Limits
The primary steel reinforcement at corbel design,
Asc shall not be less than 0.04 fc‘ bw d /fy
The horizontal closed stirrups,
Ah shall not be less than 0.5 (Asc – An)
Distribution of Corbel Reinforcement
The horizontal closed stirrups, Ah shall be distributed uniformly within (2/3) d adjacent to primary tension reinforcement.
Design Procedure
Step 1. Find factored shear Vu and tensile force Nuc
If Nuc is not specified, use a minimum value of Nuc = 0.2 Vu(ACI 11.9.3.4)
Compute nominal values of shear and tensile force
Vn = Vu / 0.75 ; Nnc = Nuc / 0.75
If Vn > 0.2 fc’ b d OR
Vn > 5.5 b d then section size is inadequate (ACI 11.9.3.2)
Step 2. Compute shear-friction reinforcement (ACI 11.7.4.1)
Avf = Vn /μ fy
Step 3. Calculate required flexural reinforcement (11.9.3.3)
Mu = Vu av + Nuc (h – d)
Corbel For Corners
Af = Mu / ϕ fy (jd) (assume jd = 0.85d)
Step 4. Reinforcement to carry tensile force (ACI 11.9.3.4)
An = Nuc / ϕfy
Step 5. Required main flexural steel (Asc) is given by (ACI 11.9.3.5 and 11.9.5)
the larger of
Af + An and 2Avf/3 + An
Step 6. Provide closed horizontal stirrups (ACI 11.9.4):
Ah = 0.5 (Asc – An)
Ensure adequate detailing (ACI 11.9.6 & 11.9.7)
Example
Corbel Geometri
Width of corbel, b = 300 mm
Total thickness of corbel, h = 500 mm
Depth to main reinforcement, d = 450 mm
Material Properties
Yield strength of reinforcement, fy = 415 Mpa
Compressive strength of concrete, fc’ = 35 Mpa
Normal weight concrete, λ = 1
Coefficient friction, μ = 1.4 x λ = 1.4
Design Load Data
Factored vertical load, Vu = 370 kN
Distance from face to column, a = 100 mm
Horizontal force, Nu = 75 kN
Strength reduction factor, ϕ = 0.75
Design Procedure
Step 1. Find factored shear Vu and tensile force Nuc
Vu = 370 kN
Nuc_min = 0.2 x 370 = 74 kN
Corbel Font For Mac
Nuc_act = the larger of 74 kN and 75 kN
= 75 kN
Compute nominal value of shear and tensile force
Vn = 370 / 0.75 = 493.33 kN
Nnc = Nuc / 0.75 = 100 kN
Corbel Font Free Download For Mac
Check section
0.2 x fc’x b x d = 945.0 kN > 493.33 kN
5.5 x b x d = 742.5 kN > 493.33 kN
Section is OK
Step 2. Compute shear-friction reinforcement (ACI 11.7.4.1)
Avf = Vn /μ fy = 493.33 / (1.4×415) = 849.11 mm2
Corbel For Mantel
Step 3. Calculate required flexural reinforcement (11.9.3.3)
Mu = Vu av + Nuc (h – d) = 370 x 1000 x 100 + 75 x 1000 (500-450)
Af = Mu / ϕ fy (0.85d) =342.28 mm2
Step 4. Reinforcement to carry tensile force (ACI 11.9.3.4)
An = Nuc / ϕfy = 75×1000 / 0.75×415 =240.96 mm2
Step 5. Required main flexural steel (Asc) is given by (ACI 11.9.3.5 and 11.9.5)
Af + An = 342.28 + 240.96 = 583.25 mm2
2Avf/3 + An = 2/3 849.11 + 240.96 = 807.04 mm2
Asc = 807.04 mm2
Use 3 dia 20 bars
Asc_prov = 3 x 314 = 942 mm2
Step 6. Provide closed horizontal stirrups (ACI 11.9.4):
Ah = 0.5 (Asc – An)= 0.5(807.04 – 240.96) =283.04 mm2
Use 3 dia 8 bars
Ah_prov=2×3×50 = 300 mm2
Sh = (2×d/3)/3 = (2×450/3)/3 = 100 mm
Detailed reinforcement